Network protocols
7.1 IPv4 protocol
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
297
Result
The assignment of the IP address to a VLAN interface is deleted and DHCP is disabled.
Note
Effectiveness of the command
The command is effective immediat
ely.
If you configure the interface via which you access the device, you can lose the connection!
Further notes
You configure the setting with the ip address command.
You display this setting and other information with the
show ip interface command.
7.1.3.3
ip address dhcp
Description
With this command, the VLAN interface obtains the IP address via DHCP.
Requirement
You are in the Interface Configuration mode of VLAN.
The command prompt is as follows:
cli(config-if-vlan-$$$)#
Syntax
Call the command without parameters:
ip address dhcp
Result
The DHCP assigns the IP address to the VLAN interface.
Further notes
You delete the settings with the no ip address command.
You display this setting and other information with the
show ip interface command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals