EasyManuals Logo

Siemens SIMATIC NET Configuration Manual

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #229 background imageLoading...
Page #229 background image
Network structures
6.2 VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
229
6.2.3
Commands in the interface configuration mode
This section describes commands that you can call up in the interface configuration mode.
Depending on the Interface selected, various command sets are available.
In the Global configuration mode, enter the
interface command to change to this mode.
Commands relating to other topics that can be called in the interface configuration mode can
be found in the relevant sections.
If you exit the Interface configuration mode with the
exit command, you return to the
Global configuration mode.
If you exit the Interface configuration mode with the
end command, you return to the
Privileged EXEC mode.
6.2.3.1
switchport acceptable-frame-type
Description
With this command, you configure which types of frames the interface accepts.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
switchport acceptable-frame-type{all|tagged}
The parameters have the following meaning:
Parameters
Description
all
All frames (with and without VLAN variables) are accepted
tagged
Only frames with VLAN variables are accepted
At system start or when using the restart command with the option memoryor factory, the
following defaults apply:
The function is configured for
all.
Result
The setting is enabled.
Further notes
You can display the status of this function and other information with the show vlan port
config
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals