Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
444 Configuration Manual, 10/2015, C79000-G8976-C351-05
11.1.6.3
no client config
Description
With this command, you disable one of the clients that processes or forwards the messages
of the device.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no client config {syslog|trap|email|all}
The parameters have the following meaning:
Parameter
Description
syslog
Disables the client that sends the messages to the Syslog server
trap
Disables the client that sends the SNMP traps
email
Disables the client that sends the e-mails
all
Disables all clients at once
Result
The client selected for the transfer is disabled.
Further notes
You display the status of the events and the clients with the show events config command.
You enable the function with the
client config command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals