Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
270 Configuration Manual, 10/2015, C79000-G8976-C351-05
The parameters have the following meaning:
Parameter
Description
Range of values / note
disable
The transfer of BPDU packets is disa-
bled for the port
Default: disabled
enable
The transfer of BPDU packets is ena-
bled for the port
-
Result
The BPDU transmit status is configured.
6.3.4.6
spanning-tree bpdu-receive
Description
With this command, you enable or disable the BPDU receive status at the port.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree bpdu-receive{enabled|disabled}
The parameters have the following meaning:
Parameter
Description
Range of values / note
enabled
BPDU packets are received at the port
Default: enabled
disabled
BPDU packets are ignored at the port
-
Result
The BPDU receive status is enabled or disabled.
Further notes
You can display the status of this function and other information with the show spanning-tree
interface
command with the detail option.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals