Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
135
6.1.1.5
show wlan advanced-11n
Description
The command shows the 802.11n configuration.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
show wlan advanced-11n <wlan 0/X>
The parameter has the following meaning:
Parameter
Description
Range of values / note
wlan 0/X
WLAN interface
Enter a valid interface.
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The following 802.11n configuration is displayed:
A-MPDU
A-MPDU limit [frames]
A-MPDU limit [bytes]
Guard Interval (only with access points)
6.1.1.6
show wlan available-ap-list (client)
Description
This command shows the access points to which the client device can establish a wireless
link or with which the client device is connected.
Note
This command is only available in the client mode.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals