System time
5.3 SNTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
127
5.3.3.1
sntp time diff
Description
With this command, you configure the time difference of the system time relative to the UTC
time.
Requirement
The SNTP server must have started up.
You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
Description
+
Time zones to the west of the SNTP server time zone
-
Time zones to the east of the SNTP server time zone
hh
Number of hours difference
mm
Number of minutes difference
Enter the time difference as follows:
with sign
without spaces
Hours and minutes both two digits (with leading zero)
Default: no time difference
Result
The time zone of the system time is configured.
Further notes
You can display the settings of this function and other information with the show sntp
status
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals