Network structures
6.2 VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
224 Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call the command without parameters:
mac-address-table aging
Result
The "Aging" function is enabled.
Further notes
You configure the time with the mac-address-table aging-time command.
You disable the "Aging" function with the
no mac-address-table aging command.
6.2.2.2
no mac-address-table aging
Description
With this command, you disable the "Aging" function.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no mac-address-table aging
Result
The "Aging" function is disabled.
Further notes
You enable the "Aging" function with the mac-address-table aging command.