Loading...
Network protocols
7.1 IPv4 protocol
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
287
7.1.2.1
telnet-server
Description
With this command, you enable the Telnet server.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
telnet-server
As default the function is "enabled".
Result
The Telnet server is enabled.
Further notes
You disable the Telnet server with the no telnet-server command.
7.1.2.2
no telnet-server
Description
With this command, you disable the Telnet server.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no telnet-server
Result
The Telnet server is disabled.
Further notes
You enable the Telnet server with the telnet-server command.

Table of Contents