Configuration
3.2 Load and Save
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
72 Configuration Manual, 10/2015, C79000-G8976-C351-05
3.2.3
load tftp
Description
With this command, you load the files from a TFTP server.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
load tftp {ipv4 <ucast_addr> | fqdn-name <FQDN>} [port <tcp port (1-65535)>] file
<filename> filetype <filetype>
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
ucast_addr
IPv4 unicast address of the TFTP
server
Enter a valid unicast IPv4 ad-
dress.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name) of the TFTP server
Maximum of 100 characters
port
Keyword for the port of the server via
which the TFTP connection runs
-
tcp port
Number of the port
1 … 65535
file
Keyword for a file name to be assigned
-
filename
Name of the file
Maximum of 100 characters
filetype
Keyword for the file type to be loaded
-
filetype
Name of the file type
Maximum of 100 characters
For information on identifiers of addresses and interfaces, refer to the section "Auto-
Hotspot".
For information on the file types , refer to this list.
Result
The file is loaded on the device from the TFTP server.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals