Network protocols
7.1 IPv4 protocol
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
289
7.1.2.5
ip route
Description
With this command, you configure a static entry in the IP routing table.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip route <gateway>
The parameter has the following meaning:
Parameter
Description
Range of values / note
gateway
Specifies the IP address of the gateway
enter a valid IP address
Result
The entry is configured.
Further notes
You delete an entry from the IP routing table with the no ip route command.
You display the IP routing table with the
show ip route command.
7.1.2.6
no ip route
Description
With this command, you delete a static entry from the IP routing table.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals