Network protocols
7.6 HTTP server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
359
7.5.2.6
no smtp-port
Description
With this command, you reset the SMTP port to the default.
The default value is 25.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
no smtp-port
Result
The SMTP port is reset to the default value.
Further notes
You configure the setting with the smtp-port command.
You display the setting with the
show smtp-port command.
7.6
HTTP server
This section describes commands of the Hypertext Transfer Protocol (HTTP).
7.6.1
The "show" commands
This section describes commands with which you display various settings.
With the command
do [command] you can execute the "show" commands in every
configuration mode.
To do this, you replace
[command] with the "show" command that you want to execute.
Example
do show cli-console-timeout

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals