Page #180 background imageLoading...
Page #180 background image
Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
180 Configuration Manual, 10/2015, C79000-G8976-C351-05
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11n or IEEE 802.11n only is set.
Syntax
Call the command without parameter assignment:
wlan data rates-11n selected only
Result
The function is enabled.
Further notes
You display the setting with the show wlan data rates command.
You disable the function with the
no wlan data rates-11n selected only command.
You configure the data transmission speeds with the
wlan data rate-11n command.
You configure the transmission standard with the
wlan mode command.
6.1.5.28
no wlan data rates-11n selected only (access point)
Description
With this command, you enable / disable the automatic selection of the data transmission
speed.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11n or IEEE 802.11n only is set.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals