Configuration
3.1 System
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
61
3.1.10.3
duplex
Description
Electrical interfaces can be operated in full duplex mode or half duplex mode. The options
here depend on the connected device.
Optical connections are always operated in full duplex mode since they have a fiber for each
transmission direction.
With this command, you configure the duplex mode of an interface. The same mode must be
set for connected interfaces.
Requirement
Autonegotiation is disabled.
You are in the Interface configuration mode of an electrical interface.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
duplex {full|half}
The parameters have the following meaning:
Parameter
Description
Range of values / note
full
The Interface will be operated in full
duplex mode.
Default: full
half
The Interface will be operated in half
duplex mode
-
Result
The duplex mode of the interface is configured.
Further notes
You can reset the duplex mode of the Interface to the default value with the no duplex
command.
You disable autonegotiation with the
no negotiation command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals