EasyManua.ls Logo

Siemens SIMATIC NET

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
261
6.3.3.15
no spanning-tree priority
Description
With this command, you reset the priority of the device back to the default value.
The default value is 32768.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no spanning-tree[mst <instance-id(1-64)>]priority
The parameters have the following meaning:
Parameter
Description
Range of values / note
mst
Keyword for a Multiple Spanning Tree
instance
-
instance-id
Number of the instance 1 ... 64
Result
The priority of the device is reset to the default value.
Further notes
You configure the setting with the spanning-tree priority command.
You display this setting and other information with the commands that start with
show
spanning-tree ...
.

Table of Contents

Other manuals for Siemens SIMATIC NET

Related product manuals