6.1.6.1
vap wds id (access point)
Description
With this command, you set the WDS ID for the relevant VAP interface. To establish a WDS
connection, enter this WDS ID on the WDS partner.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call up the command with the following parameters:
vap wds-id <wds id>
The parameter has the following meaning:
Parameter
Description
wds id
WDS ID
The WDS ID can be a maximum of 32 characters long.
Result
The WDS ID for the VAP interface is set.
Note
WDS IDs longer than 32 characters are truncated at 32 characters.
Further notes
You display the setting with the show wlan vap <vap X 0/Y>command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals