6.3.5.2
no instance
Description
With this command, you cancel the assignment of a VLAN to an MST instance or delete the
MST instance.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#
Syntax
Call up the command with the following parameters:
no instance <instance-id (1-64)> [vlan <vlan-range>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
instance-id
Number of the MST instance
1 ... 64
vlan
Keyword for a VLAN connection
-
vlan-range
Range of VLANs that will be deleted
from the instance
enter the range limts with a hy-
phen or blank
If you specify a VLAN or a VLAN range, the assignment to an MST instance is canceled.
If you do not specify a VLAN, the MST instance is deleted.
Result
The assignment of a VLAN to an MST instance is canceled or the MST instance is deleted.
Further notes
You assign a VLAN to an MST instance with the instance command.
You display this setting and other information with the
show spanning-tree mst
configuration
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals