System time
5.3 SNTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
129
5.3.3.3
no sntp unicast-server
Description
With this command, you delete the attributes for an SNTP unicast server and reset the
address.
Requirement
You are in the SNTP configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
no sntp unicast-server {ipv4 <ucast_addr> | fqdn-name <FQDN>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IP address
-
ucast_addr
Value for an IPv4 unicast address
Enter a valid IPv4 unicast address
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
Result
The SNTP unicast server is reset to the default value.
Further notes
You configure the setting with the sntp unicast-server command.
You display this setting and other information with the
show sntp unicast–mode status
command.
5.3.3.4
sntp client addressing-mode
Description
With this command, you configure the addressing mode of the SNTP client as unicast or
broadcast.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals