System time
5.3 SNTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
130 Configuration Manual, 10/2015, C79000-G8976-C351-05
Requirement
The SNTP client is activated.
You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp client addressing-mode{unicast|broadcast}
The parameters have the following meaning:
Parameter
Description
Range of values / note
unicast
configures the SNTP client in unicast
mode
Default: unicast enabled
broadcast
configures the SNTP client in broad-
cast mode
-
Result
The addressing mode of the SNTP client is configured.
Further notes
You display this setting and other information with the show sntp status command.
You display the settings for the unicast mode with the
show sntp unicast-mode status
command.
You display the settings for the broadcast mode with the
show sntp broadcast-mode status
command.