4.4 iPCF-MC
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
105
Syntax
Call the command without parameter assignment:
wlan ipcf-mc
Result
iPCF-MC is enabled.
Further notes
You disable iPCF-MC with the no wlan ipcf-mc command.
You display the setting with the
show wlan ipcf-mc command.
4.4.2.2
no wlan ipcf-mc
Note
The command is only available with the following device:
•
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
Description
With this command, you disable iPCF-MC on this SCALANCE W700 device.
Requirement
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call the command without parameter assignment:
no wlan ipcf-mc
Result
iPCF-MC is disabled.
Further notes
You enable iPCF-MC with the wlan ipcf-mc command.
You display the setting with the
show wlan ipcf-mc command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals