Configuration
3.4 Configuration Save & Restore
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
86 Configuration Manual, 10/2015, C79000-G8976-C351-05
You disable the function with the no auto-save command.
You can display the status of this function and other information with the
show device
information
command.
3.4.3.2
no auto-save
Description
With this command, you disable the auto save function.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no auto-save
Result
The auto save function is disabled. The Trial mode is activated.
Further notes
You enable the function with the auto-save command.
You can display the status of this function and other information with the
show device
information
command.
You save changes to the configuration in the Trial mode with the
write startupconfig
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals