7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
345
Further notes
You delete the SNMP target address with the no snmp targetaddr command.
You display the SNMP target address with the
show snmp targetaddr command.
You configure the SNMP target parameters with the
snmp targetparams command.
You display the SNMP target parameters with the
show snmp targetparam command.
7.4.2.15
no snmp targetaddr
Description
With this command, you delete the SNMP target address.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp targetaddr <TargetAddressName>
The parameter has the following meaning:
Parameter
Description
Range of values / note
TargetAddressName
SNMP target address
max. 32 characters
Result
The SNMP target address is deleted.
Further notes
You change the SNMP target address with the snmp targetaddr command.
You display the SNMP target address with the
show snmp targetaddr command.
7.4.2.16
snmp targetparams
Description
With this command, you configure the SNMP target parameters.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters: