Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
346 Configuration Manual, 10/2015, C79000-G8976-C351-05
snmp targetparams <ParamName>
user <UserName>
security-model {v1|v2c|v3{auth|noauth|priv}}
message-processing {v1|v2c|v3}[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ParamName
Name of the SNMP parameter
max. 32 characters
user
Keyword for the user name -
UserName
Value for the user name
max. 32 characters
security-model
Specifies which SNMP version is used.
With SNMPv3 a security level (authen-
tication, encryption) can also be con-
figured.
• SNMP version
–
v1
–
v2c
– v3
• Security level for v3
–
auth
Authentication enabled /
no encryption enabled
–
noauth
No authentication enabled,
no encryption enabled
–
priv
Authentication enabled /
encryption enabled
message-processing
Specifies which SNMP version is used
for processing the messages and
whether the settings remain following a
restart.
• SNMP version
–
v1
– v2c
–
v3
• Settings after the restart
–
volatile (volatile):
The settings are lost after
a restart
– nonvolatile (non-
volatile):
The settings are retained
after a restart
Keywords need to be specified.
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP target parameters are configured.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals