EasyManua.ls Logo

Siemens SIMATIC NET - Page 346

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
346 Configuration Manual, 10/2015, C79000-G8976-C351-05
snmp targetparams <ParamName>
user <UserName>
security-model {v1|v2c|v3{auth|noauth|priv}}
message-processing {v1|v2c|v3}[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ParamName
Name of the SNMP parameter
max. 32 characters
user
Keyword for the user name -
UserName
Value for the user name
max. 32 characters
security-model
Specifies which SNMP version is used.
With SNMPv3 a security level (authen-
tication, encryption) can also be con-
figured.
SNMP version
v1
v2c
v3
Security level for v3
auth
Authentication enabled /
no encryption enabled
noauth
No authentication enabled,
no encryption enabled
priv
Authentication enabled /
encryption enabled
message-processing
Specifies which SNMP version is used
for processing the messages and
whether the settings remain following a
restart.
SNMP version
v1
v2c
v3
Settings after the restart
volatile (volatile):
The settings are lost after
a restart
nonvolatile (non-
volatile):
The settings are retained
after a restart
Keywords need to be specified.
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP target parameters are configured.

Table of Contents