Network structures
6.2 VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
233
Syntax
Call up the command with the following parameters:
switchport priority default <0-7>
The parameter has the following meaning:
Parameter
Description
Range of values / note
-
Value for the priority default 0 ... 7
Default: 0
Result
The setting for the default priority of the interface is configured.
Further notes
You reset the priority default to the original default with the no switchport priority default
command.
You display this setting and other information with the
show vlan port config command.
6.2.3.7
no switchport priority default
Description
With this command, you reset the priority default for the interface to the default value.
The default value is 0.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport priority default
Result
The setting is reset to the default value.
Further notes
You configure the priority default with the switchport priority default command.
You display this setting and other information with the
show vlan port config command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals