Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
178 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.1.5.25
wlan data rates-11abg selected only (access point)
Description
With this command, you enable the "Use selected data rates only" function. Only the data
transmission speeds you specified with the
wlan data rate-11abg command are used.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11a/b/g/n is set.
Syntax
Call the command without parameter assignment:
wlan data rates-11abg selected only
Result
The function is enabled.
Further notes
You display the setting with the show wlan data rates command.
You disable the function with the
no wlan data rates-11abg selected only command.
You configure the data transmission speeds with the
wlan data rate-11abg command.
You configure the transmission standard with the
wlan mode command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals