Network structures
6.2 VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
226 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.2.2.4
no vlan
Description
With this command, you delete a VLAN on the device.
Requirement
The VLAN must not be assigned to a physical port.
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameter:
no vlan <vlan-id(2-4094)>
Parameter
Description
Range of values / note
vlan-id
Number of the addressed VLAN
2 ... 4094
The VLAN with number 1 cannot be deleted.
Result
The VLAN is deleted
Further notes
With the vlan command, you create a VLAN on the device.
You can display information about the VLAN with the
show vlan command.