D356 28 SM
Code Meaning Suggested Cause/Action
6-09 G3 ECM - ERR received
Check for a noisy line.
Adjust the tx levels of the communicating
machines.
See code 6-05.
6-10
G3 ECM - error frames
still received at the other
end after all
communication attempts
at 2400 bps
Check for line noise.
Adjust the tx level (use NCU parameter 01 or
the dedicated tx parameter for that address).
Check the line connection.
Defective remote terminal.
6-21
V.21 flag detected during
high speed modem
communication
The other terminal may be defective or
incompatible.
6-22
The machine resets the
sequence because of an
abnormal handshake in
the V.34 control channel
Check for line noise.
If the same error occurs frequently, replace the
FCU.
Defective remote terminal.
6-99
V.21 signal not stopped
within 6 s
Replace the FCU.
13-17
SIP user name
registration error
Double registration of the SIP user name.
Capacity for user-name registration in the SIP
server is not sufficient.
13-18 SIP server access error
Incorrect initial setting for the SIP server.
Defective SIP server.
14-00 SMTP Send Error
Error occurred during sending to the SMTP server.
Occurs for any error other than 14-01 to 16. For
example, the mail address of the system
administrator is not registered.