Installation Requirements
SM 1-1 D014/D015/D078/D079
Installation
1. INSTALLATION
1.1 INSTALLATION REQUIREMENTS
1.1.1 OPERATING ENVIRONMENT
1. Temperature Range
Recommended Temp.: 23°C (73.4°F)
Allowed Temp.: 10°C to 32°C (50°F to 90°F) – See the Note below
2. Humidity Range: 15% to 80% Rh
3. Ambient Illumination: Less than 1,500 lux (do not expose to direct sunlight or strong
light.)
4. Ventilation: Air must be replaced a minimum of 3 times per hour
5. Ambient Dust: Less than 0.10 mg/m
3
If the machine is installed in a location where the ambient temperature is more
than 30°C (86°F): (1) Do not run full color copying longer than 2 hours, and (2)
never turn the main power switch off immediately after a long copy job.
Leave the machine on so the fans can expel the hot air from the machine and
cool the electronic components.