Group 3000
D014/D015/D078/D079 5-132 SM
3821 ProCon OK?
Use this SP to display the history of process control executions. These SP
codes are used to troubleshoot processing control.
[0 to 99999999/1]
1 History:Last 6 History:Last 6
2 History:Last 2 7 History:Last 7
3 History:Last 3 8 History:Last 8
4 History:Last 4 9 History:Last 9
5 History:Last 5 10 History:Last 10
3900 RsetProConSP
Reset All Process Control SP Codes
Press [EXECUTE] to reset all process control related SP codes to their default
values.
3910
Forbid LD Write DFU
3920
Recovery Operation Request DFU
3930 Sheet Threshold Display
This setting determines sets the threshold to determine when the machine
switches from FC to BW printing during a long print job.
[0 to 99/0/1]
0: No switching from FC to BW
1: Switches according to print job (FC/BW)
2 to 99: Switches FC to BW based on the number of pages.