SM 5-131 D014/D015/D078/D079
Service
Tables
3817 Developer Filling: Admission
When SP3814 (Execute Developer Fill) is executed, the process control
self-check, but the MUSIC adjustment are disabled until after one of the SP
codes has been executed after developer filling:
SP3811 (Developer Setup)
SP3801 (TD Sensor Initialization)
This is the condition normally in effect. (SP codes 1 to 4 will display "1").
1 K
2 M
3 C
4 Y
Display the permission status of each PCU for developer filling
after SP3814 was executed.
1: Developer filling enabled. No process control self-check, no
MUSIC adjustment until SP3811 or SP3801 have been
execute.
0: Developer filling disabled
5
Reset Status:
All Colors
Forcibly resets the status to "0".
3820 Manual ProCon
Use these SP codes to execute process control manually.
You must do SP3820 to enable any values you change with SP3531 (Procon
Target). Use SP3561 to display the results of SP3820 execution.
Note:
Process control is disabled during machine warm-up.
If you execute this SP code during machine warm-up, "Completed" is
displayed immediately. However, the manual process control setting was
not actually done.
1 Normal ProCon Does potential control only.
2 Exe Density Adj
Does potential control and toner density
adjustment.
3 ACC RunTime ProCon
Executes process control again just before ACC
executes.