Service Call Tables
D014/D015/D078/D079 4-84 SM
4.2.9 SC900: MISCELLANEOUS
Electrical total counter error
The total counter contains something that is not a number.
SC900 D
NVRAM incorrect type
NVRAM defective
NVRAM data scrambled
Unexpected error from external source
Mechanical Counter 1 error
SC901
Mechanical Counter 1 was not
set correctly at power on, or
the operator disconnected the
counter while machine was
operating.
Mechanical Counter 1 connection
loose or defective
Mechanical Counter 1 defective
Mechanical Counter 2 error
SC902
Mechanical Counter 2 was not
set correctly at power on, or
the operator disconnected the
counter while machine was
operating.
Mechanical Counter 2 connection
loose or defective
Mechanical Counter 2 defective
SC910 External controller error 1 *GW
SC911 External controller error 2 *GW
SC912 External controller error 3 *GW
SC913 External controller error 4 *GW
B
The external controller (Fiery)
sends an error message.
Turn the machine power
OFF/ON
Rev. 05/2008
⇒