PTR Unit
SM 3-65 D014/D015/D078/D079
Replacement
Adjustment
3.5.2 DOUBLE-FEED DETECTION PHOTOSENSOR,
REGISTRATION SENSOR
1. Pull out the drawer unit.
2. Open the guide plate [A].
3. Remove:
[B] Sensor support plate ( x2)
[C] Double-feed detection photosensor (x1, x1)
[D] Registration sensor ( x1)
Reinstallation
Do the forced MUSIC adjustment with SP 2111 001