Bit Switches
D356 110 SM
Communication Switch 03 (SP No. 1-104-004)
No Function Comments
0-7
Maximum number of page
retransmissions in a G3
memory transmission
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
Communication Switch 04 - Not used (do not change the settings)
Communication Switch 05 - Not used (do not change the settings)
Communication Switch 06 - Not used (do not change the settings)
Communication Switch 07 - Not used (do not change the settings)
Communication Switch 08 - Not used (do not change the settings)
Communication Switch 09 - Not used (do not change the settings)
Communication Switch 0A (SP No. 1-104-011)
No Function Comments
0
Point of resumption of memory
transmission upon redialing
0: From the error page
1: From page 1
0: The transmission begins from the page
where transmission failed the previous time.
1: Transmission begins from the first page,
using normal memory transmission.
1-7 Not used Do not change the settings.