Service Call Tables
D014/D015/D078/D079 4-24 SM
SC396 D Drum motor error: K
SC397 D Drum motor error: M
SC398 D Drum motor error: C
SC399 D Drum motor error: Y
The motor is trying to rotate at power on or during normal operation but
there is an excessive load on the drum shaft. The motor has no traction
(due to a bent cleaning blade, for example).
Drum motor harness loose, broken, defective
Drum motor defective
DTMB defective