Service Call Tables
SM 4-75 D014/D015/D078/D079
Trouble-
shooting
SC833 D Self-diagnostic error 8: Engine I/F ASIC *GW
0F30
0F31
ASIC (Mandolin) for system
control could not be
detected. After the PCI
configuration, the device ID
for the ASIC could not be
checked.
Replace the VBCU
0F41
The read/write check done
for resident RAM on the
mother board could not be
done correctly.
Replace the VBCU.
50B1
Could not initialize or read
the bus connection.
Check for loose connections at
VBCU.
Replace VBCU
50B2
Value of the SSCG register
is incorrect.
Check for loose connections at
VBCU.
Replace VBCU
SC834 D Self-diagnostic error 9: Optional Memory RAM DIMM
5101
The write/verify check for the
optional RAM chip on the
controller board returned an
error.
Controller defective
Net I/F error
SC850 B
Duplicate IP addresses.
Illegal IP address.
Driver unstable and cannot
be used on the network.
IP address setting incorrect
Ethernet board defective
Controller board defective