Group 1000
D014/D015/D078/D079 5-4 SM
1008 Reg Roller Adj
Sets the length of time the paper is force pre-fed and stopped at the registration
roller for normal speed and half-speed.
1 Normal Speed [-3 to +3/ 0 /0.1
2 Half Speed [-3 to +3/ -0.6 /0.1
1009 PreFeed Time Adj
Sets the length of time the paper is force pre-fed and stopped at the registration
roller for each paper feed source..
[0 to 3/ 0 / 1]
1 Tray 1
2 Tray 2
3 Tray 3
4 Tray 4
5 LCT 1
6 LCT 2
7 Bypass Tray