Group 1000
D014/D015/D078/D079 5-8 SM
1013
Motor Adj.: Half 1 DFU
These SP codes are used to adjust the speed of the motors for Half speed 1.
[-3 to 3/0/0.1
5 K Dev Motor
6 M Dev Motor
7 C Dev Motor
8 Y Dev Motor
9 K Drum CL Mtr
10 M Drum CL Mtr
11 C Drum CL Mtr
12 Y Drum CL Mtr
13 ITB Motor
14 PTR Motor
15 Fusing Motor
1105
Hot, Htg, Press Roll Temp DFU
[140 to 200/ 170 / 1 deg.]
1 Htg Roll Ctr:Reload
2 Htg Roll Ctr:Idle:Reload
3 Htg Roll Ctr:Wait:Norm
4 Htg Roll Ctr:Wait:Low
5 Htg Roll Ctr:Wait:High
6 Htg Roll Ctr:1-S:Norm1:Normal