Group 2000
D014/D015/D078/D079 5-52 SM
2222 Execute Wire Cleaning
These SP codes manually execute wire cleaning (K PCU) and charge roller
cleaning (YMC PCUs).
1 K
2 Y,M,C
3 M
4 C
5 Y
2223 OPC Rev After Idle Time
These SP codes allow you to set up how long the OPC will idle at the start of a
print job after it has remained inactive.
1 Execution Setting
Switches this SP code on/off. Default: Off (0)
This SP must be set on for the other values (2 to
5 below) to take effect.
2 Execution Timing
Sets the amount of time for the OPC drum to idle
before the start of the job.
[0 to 360/ */1 sec.]
* Default setting:
D014/D078: 75 sec.
D015/D079: 60 sec.
3 Exec Threshold:Rel Humidity
Sets the threshold of relative humidity to trigger
idling of the OPCu.
[0 to 99/ 65/ 1 %rH]
4 Exec Threshold:Idle Time
Sets the length of time for the OPC to idle, once
the idle time has been triggered by the rH
threshold.
[0 to 6000/ 360/ 10 min.]
5 Exec Threshold:OPC Usage Sets the threshold value to trigger OPC idling,