Group 5000
D014/D015/D078/D079 5-166 SM
Determines whether the system waits the prescribed time for input of a
correct user ID and password after an account lockout has occurred.
[0 to 1/0/1]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct user ID and password are
entered.
4
Cancellation Time
Determines the length of time that the system waits for correct input of the
user ID and password after a lockout has occurred. This setting is used
only if SP5413-3 is set to "1" (on).
[1 to 999/60/1 min.]
5414 Access Mitigation
1
Mitigation On/Off
Switches on/off masking of continuously used IDs and passwords that are
identical.
[0 to 1/0/1]
0: Off
1: On
2
Mitigation Time
Sets the length of time for excluding continuous access for identical user
IDs and passwords.
[0 to 60/15/1 min.]