Group 5000
D014/D015/D078/D079 5-170 SM
Authentication Error Code
5481
These SP codes determine how the authentication failures are displayed.
1
System Log Disp
Determines whether an error code appears in the system log after a user
authentication failure occurs.
[0 to 1/0/1]
0: Off
1: On
2
Panel Disp
Determines whether an error code appears on the operation panel after a
user authentication failure occurs.
[0 to 1/1/1]
1: On
0: Off
MF Keycard Japan Only
5490
Sets up operation of the machine with a keycard.
[0 to 1/0/1]
0: Disabled. Cancels operation if no code is input.
1: Enabled. Allows operation if another code is input and decrements the
counter once for use of the entered code.
5501 PM Alarm
Sets the count level for the PM alarm.
[0 to 9999/1]
0: Alarm disabled
The PM alarm goes off when the print count reaches this value multiplied by
1,000.
CÓPIA NÃO CONTROLADA