EasyManua.ls Logo

Ricoh D014 - Page 768

Ricoh D014
1622 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Group 5000
D014/D015/D078/D079 5-226 SM
Stamp Data Download
5853
Touch [EXECUTE] to download the fixed stamp data from the machine ROM
onto the hard disk. Then these stamps can be used by the system. If this is not
done, the user will not have access to the fixed stamps ("Confidential", "Secret",
etc.).
You must always execute this SP after replacing the HDD or after formatting the
HDD. Always switch the machine off and on after executing this SP.
Remote ROM Update
5856
When set to "1" allows reception of firmware data via the local port (IEEE 1284)
during a remote ROM update. This setting is reset to zero after the machine is
cycled off and on. Allows the technician to upgrade the firmware using a parallel
cable
[0 to 1/1]
0: Not allowed
1: Allowed
5857 Save Debug Log
On/Off (1:ON 0:OFF)
1
Switches on the debug log feature. The debug log cannot be captured until this
feature is switched on.
[0 to 1/1]
0: OFF
1: ON
Target (2: HDD 3: SD Card)
2
Selects the destination where the debugging information generated by the event
selected by SP5858 will be stored if an error is generated
[2 to 3 /1]
CÓPIA NÃO CONTROLADA