Page #202 background image
Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
202 Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call up the command with the following parameters:
wlan mode { show-modes | [2.4 | 5] <mode>}
The parameters have the following meaning:
Parameters
Description
Range of values / note
show-
modes
Lists the transmission standards. --
2.4
Optional. You can use the parameter in
conjunction with "auto" and "n". This
only takes into account the transmis-
sion standard for 2.4 GHz.
Use the parameter if the client operates
in dual-frequency mode.
--
5
Optional. You can use the parameter in
conjunction with "auto" and "n". This
only takes into account the transmis-
sion standard for 5 GHz.
Use the parameter if the client operates
in dual-frequency mode.
--
mode
Value corresponding to a specific
transmission standard.
•
auto
The transmission standard is detected
automatically.
•
a
IEEE 802.11a (5 GHz)
• g
IEEE 802.11g (2.4 GHz)
Is downwards compatible with IEEE
802.11b
•
n
IEEE 802.11n (2.4 GHz + 5 GHz)
Is downwards compatible with IEEE
802.11a and IEEE 802.11g
•
n-only
IEEE 802.11n (2.4 GHz + 5 GHz)
Is not downwards compatible with IEEE
802.11a and IEEE 802.11g
Depending on the current configuration, some settings are not possible. In this case, a
message to this effect is displayed.
Result
The transmission standard is specified.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals