Concepts and features
R&S
®
ZNB/ZNBT
112User Manual 1173.9163.02 ─ 62
4.2.1.4 Channel list and channel settings
The main properties of all channels assigned to the traces in the diagram are displayed
in the channel list below the diagram.
Each line in the channel list describes a single channel. The channel of the active trace
is highlighted. The lines are divided into several sections with the following contents
(from left to right):
The "Channel Name" appears in the first section. The default names for new chan-
nels are Ch<n> with an automatically assigned number <n>. If a time domain
transform is active, the R&S ZNB/ZNBT displays an additional line to indicate the
stimulus range of the displayed time-domain trace.
Open the "Channel Manager" from the name segment's context menu to change
the channel name.
The measurement mode identifier section (optional) indicates a special test
mode of the channel, e.g. the measurement at arbitrary port frequencies ("Arb Port
n").
Start indicates the lowest value of the sweep variable (e.g. the lowest frequency
measured), corresponding to the left edge of a Cartesian diagram.
The color legend shows the display color of all traces assigned to the channel.
The colors are different, so the number of colors is equal to the numbers of traces
assigned to the channel.
The values behind the color legend show the constant stimulus value, which is
either the power of the internal signal source (for frequency sweeps and time
sweeps) or the CW frequency (for power sweeps), and the measurement band-
width ("BW").
Stop indicates the highest value of the sweep variable (e.g. the highest frequency
measured), corresponding to the right edge of a Cartesian diagram.
Open a segment's context menu to access common related tasks.
Example:
The following context menu is assigned to the channel name section:
The settings in the context menus correspond to the most common functions in the
Channel – [Channel Config] > "Channels" softtool tab, the "Stimulus" softtool (opened
Screen elements