R&S
®
ZNB/ZNBT
940User Manual 1173.9163.02 ─ 62
Example:
*RST; :CALC:LIM:CONT 1 GHZ, 2 GHZ
Define an upper limit line segment in the stimulus range
between 1 GHz and 2 GHz, using default response values.
CALC:LIM:STAT ON; TTL2 ON
Switch the limit check on and activate the TTL out pass 2 signal.
Manual operation: See "TTL1 Pass / TTL2 Pass" on page 376
7.3.1.8 CALCulate:MARKer...
The CALCulate:MARKer... commands control the marker functions. The com-
mands are device-specific and beyond what is specified in the SCPI subsystem
SOURce:MARKer....
Marker addressing
For all these commands, markers are addressed via:
1. Channel number <Chn>
The command operates on the active trace of channel <Chn>.
2. Marker number <Mk>
Selects a particular marker (ignored for reference markers).
The command operates on marker <Mk> of channel <Chn>'s active trace.
CALCulate<Chn>:MARKer<Mk>:AOFF............................................................................ 941
CALCulate<Chn>:MARKer<Mk>:BWIDth..........................................................................942
CALCulate:MARKer:COUPled[:STATe]............................................................................. 943
CALCulate:MARKer:COUPled:TYPE................................................................................943
CALCulate<Chn>:MARKer:DEFault:FORMat....................................................................944
CALCulate<Chn>:MARKer<Mk>:DELTa[:STATe]............................................................... 946
CALCulate<Chn>:MARKer<Mk>:EXCursion..................................................................... 946
CALCulate<Chn>:MARKer<Mk>:REFerence:EXCursion....................................................946
CALCulate<Chn>:MARKer<Mk>:EXCursion:STATe........................................................... 946
CALCulate<Chn>:MARKer<Mk>:REFerence:EXCursion:STATe..........................................946
CALCulate<Chn>:MARKer<Mk>:FORMat........................................................................ 947
CALCulate<Chn>:MARKer<Mk>:REFerence:FORMat....................................................... 947
CALCulate:MARKer:FUNCtion:BWIDth:GMCenter............................................................ 947
CALCulate<Chn>:MARKer<Mk>:FUNCtion:BWIDth:MODE................................................948
CALCulate<Chn>:MARKer<Mk>:FUNCtion:CENTer.......................................................... 948
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:CENTer......................................... 948
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER[:RANGe]..................................949
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:DOMain:USER[:RANGe].................949
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:SHOW.....................................949
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:DOMain:USER:SHOW....................949
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STARt......................................950
CALCulate<Chn>:MARKer<Mk>:FUNCtion:DOMain:USER:STOP...................................... 950
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:DOMain:USER:STARt.................... 950
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:DOMain:USER:STOP.....................950
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute........................................................ 950
SCPI command reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ZNB Series and is the answer not in the manual?

R&S ZNB Series Specifications

General IconGeneral
BrandR&S
ModelZNB Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals