Command reference
R&S
®
ZNB/ZNBT
1245User Manual 1173.9163.02 ─ 62
Manual operation: See "Cable" on page 541
[SENSe<Ch>:]CORRection:METas[:STATe] <Boolean>
After a successful METAS calibration, this command activates or deactivates the
uncertainty calculation for the related channel.
Suffix:
<Ch>
.
Channel number
Parameters:
<Boolean> ON (1)
METAS calibration active
OFF (0)
METAS calibration inactive
Options: R&S ZNB-K50
Manual operation: See "METAS Cal Active" on page 538
7.3.14.8
[SENSe:]CORRection... (other)
The remaining [SENSe:]CORRection... commands.
[SENSe<Ch>:]CORRection:CDATa................................................................................1246
[SENSe<Ch>:]CORRection:CDATa:PORT<PhyPt>..........................................................1246
[SENSe<Ch>:]CORRection:CONNection........................................................................1248
[SENSe<Ch>:]CORRection:CONNection:CATalog?......................................................... 1249
[SENSe<Ch>:]CORRection:CONNection:DELete............................................................ 1250
[SENSe<Ch>:]CORRection:DATA:PARameter<Sfk>?...................................................... 1251
[SENSe<Ch>:]CORRection:DATA:PARameter<Sfk>:PORT<PhyPt>?................................1251
[SENSe<Ch>:]CORRection:DATA:PARameter:COUNt?................................................... 1253
[SENSe<Ch>:]CORRection:DATE?................................................................................1253
[SENSe<Ch>:]CORRection:DELete............................................................................... 1254
[SENSe<Ch>:]CORRection:EDELay:AUTO.................................................................... 1254
[SENSe<Ch>:]CORRection:EDELay<PhyPt>:DIELectric..................................................1255
[SENSe<Ch>:]CORRection:EDELay<PhyPt>:DISTance...................................................1255
[SENSe<Ch>:]CORRection:EDELay<PhyPt>:ELENgth....................................................1255
[SENSe<Ch>:]CORRection:EDELay<PhyPt>[:TIME]....................................................... 1256
[SENSe:]CORRection:EDELay:VNETwork......................................................................1256
[SENSe<Ch>:]CORRection:LOSS<PhyPt>.....................................................................1257
[SENSe<Ch>:]CORRection:LOSS<PhyPt>:SECond........................................................1257
[SENSe<Ch>:]CORRection:LOSS:AUTO....................................................................... 1257
[SENSe<Ch>:]CORRection:LOSS<PhyPt>:FREQuency.................................................. 1258
[SENSe<Ch>:]CORRection:LOSS<PhyPt>:SECond:FREQuency..................................... 1258
[SENSe<Ch>:]CORRection:LOSS<PhyPt>:OFFSet.........................................................1258
[SENSe<Ch>:]CORRection:LOSS<PhyPt>:SECond:STATe..............................................1258
[SENSe<Ch>:]CORRection:OFFSet<PhyPt>:COMPensation[:STATe]............................... 1259
[SENSe<Ch>:]CORRection:OFFSet<PhyPt>:DFComp[:STATe]?.......................................1259
[SENSe<Ch>:]CORRection:OFFSet<PhyPt>[:STATe]...................................................... 1260
[SENSe<Ch>:]CORRection:PCAL................................................................................. 1260
SCPI command reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ZNB Series and is the answer not in the manual?

R&S ZNB Series Specifications

General IconGeneral
BrandR&S
ModelZNB Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals