<Seg> Sweep segment number. This suffix is ignored; the command
returns the sum of all segments.
Example: See [SENSe<Ch>:]SEGMent<Seg>:SWEep:TIME
Usage: Query only
Manual operation: See "Optional Columns" on page 435
7.3.14.16 [SENSe:]SWEep...
The [SENSe:]SWEep... commands provide general settings to control the sweep.
Most of the settings have an impact on the sweep time.
[SENSe<Ch>:]SWEep:AXIS:FREQuency....................................................................... 1319
[SENSe<Ch>:]SWEep:AXIS:POWer.............................................................................. 1320
[SENSe<Ch>:]SWEep:COUNt.......................................................................................1321
[SENSe:]SWEep:COUNt:ALL........................................................................................1321
[SENSe<Ch>:]SWEep:DETector:TIME........................................................................... 1322
[SENSe<Ch>:]SWEep:DWELl....................................................................................... 1322
[SENSe<Ch>:]SWEep:DWELl:IPOint............................................................................. 1323
[SENSe<Ch>:]SWEep:GENeration................................................................................ 1323
[SENSe<Ch>:]SWEep:GENeration:ANALog:CONDition?................................................. 1324
[SENSe<Ch>:]SWEep:POINts.......................................................................................1324
[SENSe<Chn>:]SWEep:SRCPort...................................................................................1325
[SENSe<Ch>:]SWEep:STEP.........................................................................................1325
[SENSe<Ch>:]SWEep:TIME......................................................................................... 1326
[SENSe<Ch>:]SWEep:TIME:AUTO................................................................................1327
[SENSe<Ch>:]SWEep:TYPE.........................................................................................1328
[SENSe<Ch>:]SWEep:AXIS:FREQuency <Scale>
Selects either the channel base frequency or one of the port frequencies as the stimu-
lus axis in all diagrams of the active recall set. This command has no effect if no port-
specific frequencies are defined.
Suffix:
<Ch>
.
Channel number
Parameters:
<Scale> String parameter, one of the following signals:
'Channel Base; Source' - base channel frequency
'Port 1; Source' - source frequency at port 1
'Port 2; Source' - source frequency at port 2
...
'Gen 1; Source' - external generator frequency 1
...
'Pmtr 1; Receiver' - external power meter frequency 1
...
*RST: 'Channel Base: Source'