7.3.14.5 [SENSe:]CORRection:CKIT... with Labels
The following [SENSe:]CORRection:CKIT... commands identify the calibration kit
to be used by a combination of its <CalkitName> and <CalkitLabel>. Typically, the
serial number of the calibration kit serves as a calibration kit label. Due to their different
labels, the analyzer can handle several calibration kits with identical names.
[SENSe:]CORRection:CKIT:LCATalog?.......................................................................... 1201
[SENSe:]CORRection:CKIT:LDELete............................................................................. 1201
[SENSe:]CORRection:CKIT:LLABel............................................................................... 1202
[SENSe:]CORRection:CKIT:LSELect..............................................................................1202
[SENSe:]CORRection:CKIT:<ConnType>:LSELect.......................................................... 1203
[SENSe:]CORRection:CKIT:STANdard:LCATalog?...........................................................1204
[SENSe:]CORRection:CKIT:<StandardType>:WLABel..................................................... 1204
[SENSe:]CORRection:CKIT:<OnePortStandardType>:WLABel:SDATa?.............................1205
[SENSe:]CORRection:CKIT:<TwoPortStandard>:WLABel:SDATa?.................................... 1205
[SENSe:]CORRection:CKIT:LCATalog? [<ConnectorType>]
Returns a list of all cal kits and their labels for a given connector type or for all connec-
tor types.
Query parameters:
<ConnectorType> Name of the connector type. Use [SENSe<Ch>:
]CORRection:CONNection:CATalog? to query connector
names.
If omitted, the command returns the list of all cal kits andlabels.
Example: See [SENSe<Ch>:]CORRection:CONNection:CATalog?
Usage: Query only
[SENSe:]CORRection:CKIT:LDELete <CalKitName>, <KitLabel>
Deletes an imported or user-defined cal kit which is identified by its cal kit name and
label.
Note: It is not possible to modify or store predefined or ideal kits.
Setting parameters:
<CalKitName> String parameter containing an imported or user-defined calibra-
tion kit available on the analyzer.
<KitLabel> String parameter containing the label of an imported or user-
defined calibration kit available on the analyzer.
Example: See [SENSe:]CORRection:CKIT:LLABel