CALCulate:FMODel:ISD...
Commands for AtaiTec's In Situ De-Embedding (ISD) tool, see http://ataitec.com/prod-
ucts/isd/
CALCulate:FMODel:ISD:ATTenuation:BEHavior................................................................908
CALCulate:FMODel:ISD:COUPon:MEASure.....................................................................909
CALCulate:FMODel:ISD:COUPon:MEASure:FILename..................................................... 909
CALCulate:FMODel:ISD:COUPon:MEASure:FILename:CLEar........................................... 909
CALCulate:FMODel:ISD:COUPon:MEASure:OPEN...........................................................909
CALCulate:FMODel:ISD:COUPon:MEASure:OPEN:FILename........................................... 910
CALCulate:FMODel:ISD:COUPon:MEASure:SHORt..........................................................910
CALCulate:FMODel:ISD:COUPon:MEASure:SHORt:FILename.......................................... 910
CALCulate:FMODel:ISD<Ph_pt>:COUPon[:STATe]........................................................... 910
CALCulate:FMODel:ISD:COUPon:TYPE.......................................................................... 911
CALCulate:FMODel:ISD:DCEXtrapolat.............................................................................911
CALCulate:FMODel:ISD:DUT:MEASure............................................................................911
CALCulate:FMODel:ISD:DUT:MEASure:FILename............................................................ 911
CALCulate:FMODel:ISD:DUT:MEASure:FILename:CLEar..................................................912
CALCulate:FMODel:ISD<Ph_pt>:DUT[:STATe]..................................................................912
CALCulate:FMODel:ISD:DUT:TYPE.................................................................................912
CALCulate:FMODel:ISD:FTIMe:DUT................................................................................912
CALCulate:FMODel:ISD:FTIMe:OVERride........................................................................913
CALCulate:FMODel:ISD:IMPedance................................................................................ 913
CALCulate:FMODel:ISD:OPERation................................................................................ 913
CALCulate:FMODel:ISD:PASSivity.................................................................................. 913
CALCulate:FMODel:ISD:PORT:ORDer.............................................................................914
CALCulate:FMODel:ISD:PORT:SKIP................................................................................914
CALCulate:FMODel:ISD:PORT:SKIP:LEFT.......................................................................914
CALCulate:FMODel:ISD:PORT:SKIP:NONE..................................................................... 914
CALCulate:FMODel:ISD:PORT:SKIP:RIGHt......................................................................914
CALCulate:FMODel:ISD:PRESet.....................................................................................915
CALCulate:FMODel:ISD:RUN:RUN................................................................................. 915
CALCulate:FMODel:ISD<Pt>:RUN[:STATe].......................................................................915
CALCulate:FMODel:ISD:SCALe:ATTenuation................................................................... 915
CALCulate:FMODel:ISD:SCALe:FREQuency....................................................................916
CALCulate:FMODel:ISD:SCALe:FTIMe............................................................................916
CALCulate:FMODel:ISD:SMALlfixture.............................................................................. 916
CALCulate:FMODel:ISD:TRACe:COUPling.......................................................................916
CALCulate:FMODel:ISD:ATTenuation:BEHavior <AttenuationBehavior>
Sets/gets the linear_2x batch mode parameter of the ISD tool
Parameters:
<AttenuationBehavior>RESonant | LINear | NONLinear
LINear
Used for linear insertion loss of test coupon (parameter value 1)
NONLinear
Used for non-linear insertion loss of test coupon (parameter
value 2)