EasyManuals Logo

R&S ZNB Series User Manual

R&S ZNB Series
1611 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1380 background imageLoading...
Page #1380 background image
Command reference
R&S
®
ZNB/ZNBT
1380User Manual 1173.9163.02 ─ 62
Setting parameters:
<Scope> ALL
If ALL is specified, all logical ports are dissolved; the <log_port>
suffix is ignored. If ALL is omitted, only the specified balanced
port is dissolved.
Example: See SOURce<Ch>:LPORt<LogPt>
Usage: Setting only
Manual operation: See "Select Predefined Port" on page 290
7.3.16 STATus commands
The STATus:... commands control the status reporting system. Status registers are
not reset by *RST; use *CLS for this purpose.
STATus:PRESet...........................................................................................................1380
STATus:QUEStionable:CONDition?................................................................................1381
STATus:QUEStionable:INTegrity:CONDition?..................................................................1381
STATus:QUEStionable:INTegrity:HARDware:CONDition?.................................................1381
STATus:QUEStionable:LIMit<Lev>:CONDition?...............................................................1381
STATus:QUEStionable:ENABle..................................................................................... 1381
STATus:QUEStionable:INTegrity:ENABle........................................................................1381
STATus:QUEStionable:INTegrity:HARDware:ENABle.......................................................1381
STATus:QUEStionable:LIMit<Lev>:ENABle.....................................................................1381
STATus:QUEStionable[:EVENt]?....................................................................................1382
STATus:QUEStionable:INTegrity[:EVENt]?......................................................................1382
STATus:QUEStionable:INTegrity:HARDware[:EVENt]?.....................................................1382
STATus:QUEStionable:LIMit<Lev>[:EVENt]?...................................................................1382
STATus:QUEStionable:NTRansition...............................................................................1382
STATus:QUEStionable:INTegrity:NTRansition................................................................. 1382
STATus:QUEStionable:INTegrity:HARDware:NTRansition................................................ 1382
STATus:QUEStionable:LIMit<Lev>:NTRansition.............................................................. 1382
STATus:QUEStionable:PTRansition............................................................................... 1382
STATus:QUEStionable:INTegrity:PTRansition................................................................. 1382
STATus:QUEStionable:INTegrity:HARDware:PTRansition................................................ 1382
STATus:QUEStionable:LIMit<Lev>:PTRansition.............................................................. 1382
STATus:QUEue[:NEXT]?.............................................................................................. 1383
STATus:PRESet
Configures the status reporting system such that device-dependent events are repor-
ted at a higher level.
The command affects only the transition filter registers, the ENABle registers, and
queue enabling:
The ENABle parts of the STATus:OPERation and STATus:QUEStionable... reg-
isters are set to all 1's.
SCPI command reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ZNB Series and is the answer not in the manual?

R&S ZNB Series Specifications

General IconGeneral
BrandR&S
ModelZNB Series
CategoryMeasuring Instruments
LanguageEnglish