Command reference
R&S
®
ZNB/ZNBT
1344User Manual 1173.9163.02 ─ 62
SOURce<Ch>:GROup<Grp>:SIMultaneous:FOFFset:MOFFset:BWFactor <arg0>
This command is related to Parallel Measurement with Frequency Offset. It defines the
multiplication factor that is used to calculate the minimum frequency offset from the
measurement bandwidth.
Note that this only takes effect if SOURce<Ch>:GROup<Grp>:SIMultaneous:
FOFFset:MOFFset:MODE is set to BANDwidth.
Suffix:
<Ch>
.
Channel number.
If unspecified, this parameter is set to 1.
<Grp>
Parameters:
<arg0> The multiplication factor to calculate the minimum frequency off-
set.
To get the resulting frequency offset, the minimum frequency off-
set is rounded to a multiple of the current frequency step size.
Range: 1 to 100
*RST: 10
Example: See SOURce<Ch>:GROup<Grp>:SIMultaneous:FOFFset:
STATe
Manual operation: See "Minimum Offset" on page 576
SOURce<Ch>:GROup<Grp>:SIMultaneous:FOFFset:MOFFset:DVALue
<StartFreq>
This command is related to Parallel Measurement with Frequency Offset. It specifies
the minimum frequency offset directly.
Note that this only takes effect if SOURce<Ch>:GROup<Grp>:SIMultaneous:
FOFFset:MOFFset:MODE is set to DIRect.
Suffix:
<Ch>
.
Channel number.
If unspecified, this parameter is set to 1.
<Grp>
Parameters:
<StartFreq> The minimum frequency offset.
To get the resulting frequency offset, the minimum frequency off-
set is rounded to a multiple of the current frequency step size.
Range: 0 Hz to 17 MHz
*RST: 1 MHz
Default unit: Hz
Example: See SOURce<Ch>:GROup<Grp>:SIMultaneous:FOFFset:
STATe
SCPI command reference