Concepts and features
R&S
®
ZNB/ZNBT
233User Manual 1173.9163.02 ─ 62
Opening Factor
This result is a measure of the effects of amplitude noise on the vertical eye open-
ing. Accordingly, it is equal to
(("Eye Top" - σ
Top
) - ("Eye Base" + σ
Base
)) / "Eye Amplitude"
SNR
Relates the "Eye Amplitude" to the noise level. Accordingly, it is equal to
"Eye Amplitude" / (σ
Top
+ σ
Base
)
Eye diagram results are only available for NRZ modulated signals.
Eye Mask Test
Furthermore, the eye diagram simulation allows to perform tests against a user-defined
eye mask:
Figure 4-20: User-defined Eye Mask
Eye mask tests are only available for NRZ modulated signals.
Rise Time Measurement
From the measured S parameters, the step responses can also be calculated using the
inverse Fourier transform. The rise time is the time the step response takes to rise from
x% to y% (0≤x≤y≤100) of the resulting step size, typically from 10% to 90%.